| Rated Power: | 50 KVA | Test Voltage: | 150 KV AC |
|---|---|---|---|
| Test Mode: | Power Frequency AC Withstand | PD Monitoring: | Supported |
| Signal Detection: | High Sensitivity | Noise Control: | Adaptive Filtering Algorithm |
| Primary Application: | High-Voltage Insulation Assessment | Applicable Objects: | Transformers, Generators, GIS, Switchgear, Capacitors, Bushings, Etc. |
| Highlight: | 50kVA AC withstand testing system,150kV high voltage insulation diagnosis,PD monitoring for transformers capacitors |
||
50kVA/150kV Power Frequency PD-Free AC Withstand Test System
For high-voltage equipment, early insulation problems can be difficult to recognize because partial discharge may occur long before a complete insulation breakdown. The 50kVA/150kV Power Frequency PD-Free AC Withstand Test System provides a testing platform for applying power-frequency AC voltage while monitoring weak discharge activity during insulation evaluation.
The system is designed for a wide range of equipment such as transformers, instrument transformers, generators, surge arresters, bushings, GIS, capacitors and switchgear. High-sensitivity signal acquisition supports detection of subtle PD activity, while the built-in adaptive filtering technology helps distinguish useful discharge signals from background electromagnetic noise. This makes the system suitable for high-voltage testing environments where stable data and accurate insulation assessment are important.
| Parameter | Value |
|---|---|
| Rated Power | 50 kVA |
| Test Voltage | 150 kV AC |
| Test Mode | Power Frequency AC Withstand |
| PD Monitoring | Supported |
| Signal Detection | High Sensitivity |
| Noise Control | Adaptive Filtering Algorithm |
| Primary Application | High-Voltage Insulation Assessment |
| Applicable Objects | Transformers, Generators, GIS, Switchgear, Capacitors, Bushings, etc. |
Q1: What is the main purpose of the system?
A: It is primarily used for power-frequency AC withstand testing with partial discharge detection for high-voltage electrical equipment.
Q2: Why is partial discharge detection useful?
A: Weak PD activity can indicate potential insulation defects before they develop into more serious insulation failures.
Q3: Can it work in environments with electromagnetic interference?
A: The system uses adaptive filtering technology to suppress background noise and improve detection stability in complex electromagnetic environments.
Q4: Which high-voltage equipment is suitable for testing?
A: Suitable applications include transformers, instrument transformers, generators, GIS, switchgear, bushings, capacitors, surge arresters and other high-voltage electrical equipment.