Product Details:
Contact Now
Chat Now
|
| Rated Capacity: | 50 KVA | Maximum Test Voltage: | 150 KV |
|---|---|---|---|
| Test Type: | Power Frequency AC Withstand Test | PD Function: | Partial Discharge Detection |
| Detection Performance: | High Sensitivity | Signal Processing: | Intelligent Adaptive Filtering |
| Main Function: | AC Insulation Withstand & PD Evaluation | Test Objects: | Transformers, Generators, GIS, Switchgear, Bushings, Capacitors, Surge Arresters, Etc. |
| Highlight: | 50 kVA AC dielectric test system,150 kV power frequency withstand tester,high-sensitivity partial discharge detector |
||
50kVA/150kV Power Frequency PD-Free AC Withstand Test System
Insulation defects in high-voltage equipment may begin with extremely weak discharge signals that are difficult to identify through conventional withstand testing alone. The 50kVA/150kV Power Frequency PD-Free AC Withstand Test System combines power-frequency AC withstand testing with sensitive partial discharge detection to provide a more comprehensive approach to electrical insulation evaluation.
The system is suitable for various voltage classes and capacities of power transformers, instrument transformers, generators, surge arresters, bushings, GIS, capacitors, switchgear and other high-voltage electrical equipment. Its high-sensitivity detection capability helps capture weak PD signals and identify potential insulation defects, while an intelligent adaptive filtering algorithm suppresses background noise and improves detection stability in complex electromagnetic environments.
|
Parameter |
Specification |
|
Rated Capacity |
50 kVA |
|
Maximum Test Voltage |
150 kV |
|
Test Type |
Power Frequency AC Withstand Test |
|
PD Function |
Partial Discharge Detection |
|
Detection Performance |
High Sensitivity |
|
Signal Processing |
Intelligent Adaptive Filtering |
|
Main Function |
AC Insulation Withstand & PD Evaluation |
|
Test Objects |
Transformers, Generators, GIS, Switchgear, Bushings, Capacitors, Surge Arresters, etc. |
Q1: What types of equipment can be tested?
A: The system can be applied to transformers, instrument transformers, generators, surge arresters, bushings, GIS, capacitors, switchgear and other suitable high-voltage equipment.
Q2: Does the system perform partial discharge detection?
A: Yes. In addition to power-frequency AC withstand testing, the system provides sensitive partial discharge detection.
Q3: How does the system deal with background noise?
A: An adaptive filtering algorithm helps suppress background interference and improve measurement stability.
Q4: What are the main system ratings?
A: The system is rated at 50kVA with a maximum test voltage of 150kV.
![]()
Contact Person: Miss. Kelly Pan
Tel: +8618186672186