Product Details:
Contact Now
Chat Now
|
| Rated Nominal Voltage: | ±400 KV | Rated Stage Voltage: | ±100 KV |
|---|---|---|---|
| Rated Energy: | 20 KJ | Number Of Stages: | 4 Stages |
| Stage Capacitance: | 1.0 μF | Total Impulse Capacitance: | 0.25 μF |
| Standard Impulse Waveform: | 1.2/50 μs Lightning Impulse Voltage Waveform | Full Capacity Charging Time: | 180 S |
| Name: | Impulse Voltage Generator | ||
| Highlight: | 4 Stages Impulse Test Equipment,400kV Lightning Impulse Test Equipment,20kJ Lightning Impulse Test Equipment |
||
400kV/20kJ Lightning Impulse Test System
The Lightning Impulse Test System is designed for insulation performance verification of high voltage electrical equipment under lightning impulse voltage conditions. The system generates standardized impulse voltage waveforms to simulate lightning overvoltage stresses and evaluate the insulation strength of transformers, GIS, cables, bushings, insulators, and other power equipment.
The impulse voltage generator adopts modular design technology with charging unit, impulse capacitors, multi-stage generator structure, control system, measurement system, and protection devices. It can generate standard lightning impulse voltage waveform (1.2/50μs) according to IEC 60060 requirements for high voltage testing applications.
| Parameter | Specification |
|---|---|
| Rated Nominal Voltage | ±400 kV |
| Rated Stage Voltage | ±100 kV |
| Rated Energy | 20 kJ |
| Number of Stages | 4 Stages |
| Stage Capacitance | 1.0 μF |
| Total Impulse Capacitance | 0.25 μF |
| Standard Impulse Waveform | 1.2/50 μs Lightning Impulse Voltage Waveform |
| Charging Voltage Stability | ≤ ±1% |
| Full Capacity Charging Time | 180 s |
| Testing Application | Transformer and High Voltage Electrical Equipment Insulation Testing |
![]()
Contact Person: Miss. Kelly Pan
Tel: +8618186672186