Product Details:
Contact Now
Chat Now
|
| Name: | Lightning Impulse Test System | Rated Voltage: | ±100 ~ ±4800 KV |
|---|---|---|---|
| Impulse Voltage Type: | Lightning Impulse Voltage And Switching Impulse Voltage | Generator Structure: | Multi Stage Marx Impulse Generator |
| Stage Voltage: | ±100 ~ ±200 KV | Stage Capacitance: | 0.325 ~ 1 μF |
| Impulse Energy: | 7.31 ~ 320 KJ | Number Of Stages: | 1 ~ 24 Stages |
| Control System: | Digital Automatic Control And Data Acquisition | ||
| Highlight: | Digital Control Lightning Impulse Test System,Automatic Lightning Impulse Test System,ISO9001 Lightning Impulse Test System |
||
SXCY Lightning Impulse Test System
Lightning Impulse Test System for Transformer Insulation Withstand Testing Equipment
The Lightning Impulse Test System is a high-voltage testing solution designed for evaluating the insulation strength of transformers and power equipment under lightning impulse conditions. The system generates standard lightning impulse voltage and switching impulse voltage to simulate transient overvoltage impact in power networks.
Based on multi-stage Marx impulse generator technology, this system provides stable output voltage, accurate waveform control, and reliable test performance. It is widely used in transformer factories, high voltage laboratories, testing centers, and research institutions for insulation withstand verification.
The equipment adopts digital automatic control and data acquisition technology, enabling engineers to control testing procedures, capture impulse waveforms, and analyze test results efficiently. Flexible configuration allows different voltage levels and energy capacities according to customer requirements.
| Parameter | Specification |
|---|---|
| Product Type | Lightning Impulse Test System |
| Rated Voltage | ±100 ~ ±4800 kV |
| Impulse Voltage Type | Lightning Impulse Voltage and Switching Impulse Voltage |
| Generator Structure | Multi Stage Marx Impulse Generator |
| Stage Voltage | ±100 ~ ±200 kV |
| Stage Capacitance | 0.325 ~ 1 μF |
| Impulse Energy | 7.31 ~ 320 kJ |
| Number of Stages | 1 ~ 24 Stages |
| Control System | Digital Automatic Control and Data Acquisition |
| Test Objects | Transformers and High Voltage Electrical Equipment |
The Lightning Impulse Test System is mainly applied for transformer insulation testing, GIS testing, switchgear testing, cable testing, and high voltage equipment performance evaluation. It helps manufacturers and laboratories verify insulation reliability before equipment operation.
Contact Person: Miss. Kelly Pan
Tel: +8618186672186