| Output Current: | 3000A Three Phase High Current Output | Name: | Temperature Rise Test Equipment |
|---|---|---|---|
| Rated Capacity: | 3-90 KVA | Current Booster Input: | 3-90 A |
| Current Booster Output: | 0.5-15 KA | Impedance Voltage: | <8% |
| No-load Current: | <6% | Structure Type: | Cabinet / Bench / Separate Type |
| Voltage Output: | 220-400V | ||
| Highlight: | 3000A Temperature Rise Test Equipment,High Current Temperature Rise Test Equipment,Temperature Rise Test Equipment Three Phase |
||
Temperature Rise Test System
The 3000A Three Phase High Current Temperature Rise Test System is designed for thermal performance testing of transformers, switchgear, busbars, and other electrical equipment. It provides stable high current output to simulate actual operating conditions and evaluate temperature rise characteristics during long-term operation.
The system integrates a current booster, voltage regulator, temperature acquisition unit, and intelligent control software. It supports automatic current adjustment, real-time temperature monitoring, and test data recording, providing accurate and reliable solutions for transformer manufacturers, testing laboratories, and electrical equipment factories.
| Model | Rated Capacity(KVA) | Current Booster Rated Input | Current Booster Rated Output | Impedance Voltage % | No-load Current % | Structure Type | |||
|---|---|---|---|---|---|---|---|---|---|
| Voltage Regulator | Current Booster | Current(A) | Voltage (V) | Current(KA) | Voltage (V) | ||||
| DDG-3/500 | 3 | 3 | 13.6 | 220 | 0.5 | 6 | <8 | <6 | Cabinet Type |
| DDG-6/1000 | 6 | 6 | 27.00 | 220 | 1 | 6 | <8 | <6 | Cabinet / Bench Type |
| DDG-9/1500A | 9 | 9 | 40.00 | 220 | 1.5 | 6 | <8 | <6 | Separate Type |
| DDG-12/2000 | 12 | 12 | 54.50 | 220 | 2 | 6 | <8 | <6 | Separate Type |
| DDG-18/3000 | 18 | 18 | 45.00 | 400 | 3 | 6 | <8 | <6 | Separate Type |
| DDG-30/5000 | 30 | 30 | 75.00 | 400 | 5 | 6 | <8 | <6 | Separate Type |
| DDG-60/10000 | 60 | 60 | 150.00 | 400 | 10 | 6 | <8 | <6 | Separate Type |
| DDG-90/15000 | 90 | 90 | 225.00 | 400 | 15 | 6 | <8 | <6 | Separate Type |
This system is widely used for power transformer and distribution transformer heat run tests to verify thermal performance, cooling capability, and operating reliability under rated load conditions.
It is suitable for switchgear, busbar, circuit breaker, and other current-carrying equipment manufacturers to perform temperature rise verification before product delivery.
Provides 3000A three-phase current output with excellent stability, ensuring accurate and repeatable temperature rise test results.
Equipped with automatic control technology for current regulation, temperature monitoring, and real-time data recording.
Supports customized design based on different current levels, test objects, laboratory conditions, and customer requirements.
Includes protection functions such as overcurrent protection, overheating protection, and emergency shutdown for safe operation.
It is used to evaluate thermal performance of transformers and electrical equipment under rated current conditions.
Yes, the current capacity can be customized according to different testing requirements.
Yes, it supports multi-channel temperature acquisition and automatic test data recording.
It can test transformers, switchgear, busbars, circuit breakers, and other electrical products.
Yes, customized high current testing solutions and laboratory integration services are available.
Contact Person: Miss. Kelly Pan
Tel: +8618186672186