GIS Partial Discharge and AC Withstand Test System for High Voltage Insulation Testing with Sealed Shielded Structure

I'm Online Chat Now

GIS Partial Discharge and AC Withstand Test System for High Voltage Insulation Testing with Sealed Shielded Structure

GIS Partial Discharge and AC Withstand Test System for High Voltage Insulation Testing with Sealed Shielded Structure
GIS Partial Discharge and AC Withstand Test System for High Voltage Insulation Testing with Sealed Shielded Structure GIS Partial Discharge and AC Withstand Test System for High Voltage Insulation Testing with Sealed Shielded Structure GIS Partial Discharge and AC Withstand Test System for High Voltage Insulation Testing with Sealed Shielded Structure GIS Partial Discharge and AC Withstand Test System for High Voltage Insulation Testing with Sealed Shielded Structure

Large Image :  GIS Partial Discharge and AC Withstand Test System for High Voltage Insulation Testing with Sealed Shielded Structure

Product Details:
Place of Origin: China
Brand Name: Sansion Power
Certification: CE/SGS/EMS/ISO 9001
Model Number: SXGTU
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Plywood Case
Delivery Time: 30 Working Days
Payment Terms: L/C,T/T
Contact Now Chat Now

GIS Partial Discharge and AC Withstand Test System for High Voltage Insulation Testing with Sealed Shielded Structure

Description
Voltage Level: 100kV / 200kV / 250kV / 300kV / 500kV / 800kV / 1000kV Capacity Range: 50–2000kVA
Input Voltage: 0.35–10kV Partial Discharge Level: 1–3pC At Rated Voltage Under Normal Environment
High Voltage Generation: High Voltage Transformer Step-up + Series Resonance (power Frequency / Variable Frequency) Testing Type: AC Withstand Voltage Testing And Partial Discharge Measurement
Equipment Type: GIS And GIL High Voltage Equipment Shielded Design: Fully Sealed In A Shielded Space
Highlight:

GIS partial discharge test system

,

AC withstand test equipment

,

high voltage insulation testing system

Product Description

SXGTU GIS Partial Discharge and Withstand Voltage Test System

The GIS Partial Discharge and Withstand Voltage Test System is designed for high voltage and large capacity GIS/GIL equipment testing. It is mainly used for AC withstand voltage testing and partial discharge measurement to evaluate insulation performance of gas insulated electrical equipment.

The system is suitable for GIS manufacturers, high voltage laboratories and power equipment testing organizations. The high voltage part is fully sealed in a shielded space to reduce external interference and achieve low partial discharge background during testing.

Product Features

  1. Integrated Withstand Voltage and Partial Discharge Testing
    Combines AC withstand voltage testing and partial discharge measurement for GIS and GIL equipment.
  2. Low Partial Discharge Background Design
    The high voltage part is fully sealed in a shielded space to reduce interference during measurement.
  3. Flexible Voltage and Capacity Configuration
    Different voltage levels and capacity configurations can be customized according to testing requirements.
  4. Suitable for Factory Testing Applications
    Designed for GIS manufacturers and high voltage laboratories requiring insulation performance verification.

Technical Parameters

Parameter

Specification

Product Name

GIS Partial Discharge and Withstand Voltage Test System

Voltage Level

100kV / 200kV / 250kV / 300kV / 500kV / 800kV / 1000kV

Capacity Range

50–2000kVA

Input Voltage

0.35–10kV

Partial Discharge Level

1–3pC at rated voltage under normal environment

High Voltage Generation Method

High voltage transformer step-up + series resonance (power frequency / variable frequency)

Applications

  • GIS manufacturer factory testing
  • GIS insulation performance testing
  • GIL high voltage equipment testing
  • High voltage laboratory testing
  • Power equipment quality inspection
  • GIS commissioning and acceptance testing

FAQ

Q1: What equipment can be tested by this system?
A: The system is mainly designed for GIS and GIL high voltage equipment testing.

Q2: What tests can this system perform?
A: It can perform AC withstand voltage testing and partial discharge measurement.

Q3: Can the voltage level be customized?
A: Yes, different voltage levels and capacity configurations can be customized according to testing requirements.

Q4: Where is this system applied?
A: It is mainly used in GIS manufacturers, high voltage laboratories and power equipment testing organizations.