Home ProductsAC High Voltage Test Equipment

GIS High Voltage Partial Discharge and AC Withstand Test System Testing Equipment for SF6 Insulated Switchgear Insulation Diagnosis

I'm Online Chat Now

GIS High Voltage Partial Discharge and AC Withstand Test System Testing Equipment for SF6 Insulated Switchgear Insulation Diagnosis

GIS High Voltage Partial Discharge and AC Withstand Test System Testing Equipment for SF6 Insulated Switchgear Insulation Diagnosis
GIS High Voltage Partial Discharge and AC Withstand Test System Testing Equipment for SF6 Insulated Switchgear Insulation Diagnosis GIS High Voltage Partial Discharge and AC Withstand Test System Testing Equipment for SF6 Insulated Switchgear Insulation Diagnosis GIS High Voltage Partial Discharge and AC Withstand Test System Testing Equipment for SF6 Insulated Switchgear Insulation Diagnosis GIS High Voltage Partial Discharge and AC Withstand Test System Testing Equipment for SF6 Insulated Switchgear Insulation Diagnosis

Large Image :  GIS High Voltage Partial Discharge and AC Withstand Test System Testing Equipment for SF6 Insulated Switchgear Insulation Diagnosis

Product Details:
Place of Origin: China
Brand Name: Sansion Power
Certification: CE/SGS/EMS/ISO 9001
Model Number: SXGTU
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Plywood Case
Delivery Time: 30 Working Days
Payment Terms: L/C,T/T
Contact Now Chat Now

GIS High Voltage Partial Discharge and AC Withstand Test System Testing Equipment for SF6 Insulated Switchgear Insulation Diagnosis

Description
Voltage: 100–1000 KV Capacity: 50–2000 KVA
Input Voltage: 0.35–10 KV HV Generation: HV Transformer / Series Resonance
Frequency: Power Frequency / Variable Frequency PD Level: 1–3 PC At Rated Voltage
Boosting Method: Single Stage Temperature Rise: ≤65 K
Highlight:

GIS high voltage partial discharge test system

,

AC withstand test equipment for SF6 switchgear

,

high voltage insulation diagnosis testing equipment

Product Description

SXGTU GIS Partial Discharge Withstand Voltage Test Device

The SXGTU GIS AC Withstand Test System provides a high voltage solution for verifying the insulation strength of SF6 Gas Insulated Switchgear. It is designed for applications where GIS assemblies need to withstand specified AC test voltages during factory inspection, type testing or other high voltage verification procedures.

The system uses a sealed high voltage structure with internal shielding and supports single-stage voltage boosting. High voltage transformer boosting and series resonance can be selected according to the required test configuration, with both power-frequency and variable-frequency solutions available. The compact structure also helps reduce the space and power supply requirements of the complete testing installation.

Product Parameters

Parameter Specification
Model SXGTU
Product Type GIS AC Withstand Test System
Voltage 100–1000 kV
Capacity 50–2000 kVA
Input Voltage 0.35–10 kV
HV Generation HV Transformer / Series Resonance
Frequency Power Frequency / Variable Frequency
PD Level 1–3 pC at Rated Voltage
Boosting Method Single Stage
Temperature Rise ≤65 K

Product Advantages

  1. The system provides high voltage AC testing capability for GIS insulation verification.
  2. Single-stage boosting avoids the need for cascade-connected transformer structures.
  3. The compact configuration is suitable for test halls where installation space is limited.
  4. Reduced system power requirements can simplify the design of the supporting electrical supply.

Application Scenarios

  • GIS AC withstand testing
  • SF6 switchgear dielectric testing
  • GIS factory acceptance testing
  • High voltage insulation verification
  • GIS type test laboratory
  • Power equipment quality testing

FAQ

Q1: What is the voltage range of the SXGTU?
A1: Standard voltage levels include 100 kV, 200 kV, 250 kV, 300 kV, 500 kV, 800 kV and 1000 kV.

Q2: What is the main purpose of AC withstand testing?
A2: It is used to verify the insulation strength of GIS and other high voltage electrical equipment under specified AC test conditions.

Q3: Is the system suitable for factory testing?
A3: Yes. It can be used for GIS factory routine testing and other production-line insulation verification.

Q4: Can higher voltage levels be supplied?
A4: Yes. Higher voltage levels can be customized according to the required test specification.