Home ProductsAC High Voltage Test Equipment

GIS AC Hipot Test System and Partial Discharge Detector for 145kV 245kV 420kV 550kV GIS Switchgear Insulation Testing

I'm Online Chat Now

GIS AC Hipot Test System and Partial Discharge Detector for 145kV 245kV 420kV 550kV GIS Switchgear Insulation Testing

GIS AC Hipot Test System and Partial Discharge Detector for 145kV 245kV 420kV 550kV GIS Switchgear Insulation Testing
GIS AC Hipot Test System and Partial Discharge Detector for 145kV 245kV 420kV 550kV GIS Switchgear Insulation Testing GIS AC Hipot Test System and Partial Discharge Detector for 145kV 245kV 420kV 550kV GIS Switchgear Insulation Testing GIS AC Hipot Test System and Partial Discharge Detector for 145kV 245kV 420kV 550kV GIS Switchgear Insulation Testing GIS AC Hipot Test System and Partial Discharge Detector for 145kV 245kV 420kV 550kV GIS Switchgear Insulation Testing

Large Image :  GIS AC Hipot Test System and Partial Discharge Detector for 145kV 245kV 420kV 550kV GIS Switchgear Insulation Testing

Product Details:
Place of Origin: China
Brand Name: Sansion Power
Certification: CE/SGS/EMS/ISO 9001
Model Number: SXGTU
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Plywood Case
Delivery Time: 30 working days
Payment Terms: L/C,T/T
Contact Now Chat Now

GIS AC Hipot Test System and Partial Discharge Detector for 145kV 245kV 420kV 550kV GIS Switchgear Insulation Testing

Description
Capacity Range: 50–2000kVA System Type: Resonance Voltage Generation
Frequency: 50Hz/60Hz Input Voltage: 0.35–10kV
Cooling Method: Air Cooling Power Consumption: 500W
Highlight:

GIS AC Hipot Test System for 550kV

,

Partial Discharge Detector for GIS Switchgear

,

AC High Voltage Test Equipment with warranty

Product Description

The GIS AC Hipot Test System and Partial Discharge Detector is designed for high-voltage GIS insulation testing across different voltage classes.

The system can be configured according to the customer's GIS rated voltage and required test voltage.

Typical Voltage Classes
  • 72.5 kV
  • 126 kV
  • 145 kV
  • 170 kV
  • 245 kV
  • 252 kV
  • 362 kV
  • 420 kV
  • 550 kV
  • Higher voltage classes

Important: the exact AC test voltage must be determined according to the applicable GIS standard, rated voltage, insulation level and project specification rather than simply selecting the highest voltage class.

Testing Functions
  • AC hipot test
  • AC withstand voltage
  • Partial discharge detection
  • PD pattern analysis
  • Insulation verification
  • High-voltage measurement
  • Automatic test control
  • Test data storage
Customer Pain Points

“Our GIS is 145kV/245kV/420kV. Which system should we choose?"

The rated voltage alone is not enough.

We normally need:

GIS rated voltage + required test voltage + GIS capacitance + test duration + frequency requirement + applicable standard.

FAQ

Q: Can you provide different voltage levels?

A: Yes. The test system can be configured for different GIS voltage classes.

Q: Can one system test different GIS voltage levels?

A: Depending on the design, the same system may cover a range of test requirements, but the final configuration should be verified against the maximum voltage, capacitance and testing procedure.

GIS AC Hipot Test System and Partial Discharge Detector for 145kV 245kV 420kV 550kV GIS Switchgear Insulation Testing

Contact Details
Sansion Power Electric Co., Ltd.

Contact Person: Miss. Kelly Pan

Tel: +8618186672186

Send your inquiry directly to us (0 / 3000)