| Name: | Partial Discharge Detection System | Voltage Level: | 100kV / 200kV / 250kV / 300kV / 500kV / 800kV / 1000kV (Customized Higher Voltage Available) |
|---|---|---|---|
| Capacity Range: | 50–2000 KVA (Customized Higher Capacity Available) | HV Generation Method: | High Voltage Transformer Boosting + Series Resonance (power Frequency / Variable Frequency) |
| Primary Input Voltage: | 0.35kV–10kV | Partial Discharge Level: | ≤1–3 PC Under Rated Voltage |
| Temperature Rise: | ≤65K After 60 Minutes Operation At Rated Current (50Hz) | ||
| Highlight: | GIS Partial Discharge Detection System,Partial Discharge Detection System 0.35kV,Partial Discharge Detection System 10kV |
||
Advanced High Voltage No Partial Discharge Testing Solution for GIS & GIL Equipment
The SXGTU GIS Partial Discharge Detection System is an advanced high voltage test solution specially developed for GIS (Gas Insulated Switchgear) and GIL (Gas Insulated Line) equipment testing.
With the continuous development of the global power grid and increasing voltage levels up to 1000kV, higher requirements are placed on high voltage test equipment. Based on advanced technology, Sansion Power has developed the SXGTU series, which provides reliable solutions for factory acceptance tests, preventive maintenance tests, and insulation performance verification of high voltage and large-capacity GIS/GIL systems.
The system is widely used by GIS manufacturers, power utilities, testing laboratories, and high-voltage equipment service organizations.
With an additional high-voltage bushing interface, the system can also be applied for testing conventional high-voltage equipment.
| Parameter | Specification |
|---|---|
| Voltage Level | 100kV / 200kV / 250kV / 300kV / 500kV / 800kV / 1000kV (Customized higher voltage available) |
| Capacity Range | 50–2000 kVA (Customized higher capacity available) |
| HV Generation Method | High voltage transformer boosting + series resonance (power frequency / variable frequency) |
| Primary Input Voltage | 0.35–10 kV |
| Partial Discharge Level | ≤1–3 pC under rated voltage |
| Temperature Rise | ≤65K after 60 minutes operation at rated current (50Hz) |
Q1: What equipment can be tested by SXGTU GIS PD Detection System?
A:
It is mainly designed for GIS, GIL, high-voltage switchgear, and other large-capacity power equipment testing. With optional interfaces, it can also test conventional high-voltage equipment.
Q2: What is the partial discharge level of the system?
A:
The system adopts a low-noise design, and the partial discharge level can be controlled within 1–3 pC under rated voltage.
Q3: Can the system be customized?
A:
Yes. Voltage level, capacity, interface design, testing configuration, and system structure can be customized according to customer requirements.
Q4: What voltage levels are available?
A:
Standard solutions cover 100kV to 1000kV voltage levels. Higher voltage classes can be customized.
Q5: What are the main applications?
A:
It is widely used for GIS/GIL factory testing, preventive maintenance, commissioning tests, and insulation performance evaluation.
![]()